![what is codemeter runtime kit what is codemeter runtime kit](https://www.grindhousedatabase.com/images/Helterskelterad.jpg)
- #What is codemeter runtime kit download for windows#
- #What is codemeter runtime kit install#
- #What is codemeter runtime kit drivers#
- #What is codemeter runtime kit update#
- #What is codemeter runtime kit software#
#What is codemeter runtime kit download for windows#
Wibu Others Driver Download For Windows Xp Enabling LoggingĬodemeter allows you to write extended log files to you local drive. Instructions for creating a diagnostics file can be found on create CM Dust diagnostics file page. When the CodeMeter runtime kit is installed a diagnostics utility call cmDust is also installed. If you are having trouble accessing a network dongle from a remote computer, please follow the steps below: If the dongle is correctly detected (the icon changes colour to green), but you are unable to run a TUFLOW simulation, please follow the steps below: If the CodeMeter icon reamins grey (not detected) when the dongle is inserted, please follow the steps below: Red, CM stick disabled (password protected). Yellow, CM stick enabled until unplugged (password protected).
#What is codemeter runtime kit drivers#
If the drivers have been installed, the colour of the CodeMeter icon in the taskbar indicates if a dongle is being detected correctly.Ī range of other colors are also available but not frequently used:
#What is codemeter runtime kit update#
When an update is applied, this modifies the content of the dongle, it does not need to be applied on each computer that will be used for TUFLOW modelling! To import the file please follow the steps below, the same method is used for network and local licences. This update file will have the extension. Once a licence update has been created, an update file will be provide to you via email.
#What is codemeter runtime kit software#
If you would like a software licence instead of a hardware licence: Wibu software licence update requestĪfter creating the licence update request, please email the created file (.If you have been provided with a blank dongle or are using a non BMT dongle the TUFLOW producer code needs to be added when requesting the licence update: Wibu licence update request (uncoded or blank dongle).Unless specified otherwise by the TUFLOW staff, this option is the correct one to chose (please click the link to the right): Wibu licence update request (normal).The instructions for creating a licence request differ slightly depending whether the dongle has not previously been coded for TUFLOW simulations or if the dongle has not been provided by BMT. The procedure is the same for local and network licences, the request will need to be generated from the computer which has the dongle plugged in. There are a number of reasons that the Wibu licence may need to be updated, for example:įor each change to the dongle, it will be necessary to provide a licence update request file to the TUFLOW staff. Once installed, CodeMeter needs to be configured to use the network licence.Instructions for configuring the network licence are detailed in the following page: To access TUFLOW licences on a remote network server, the CodeMeter runtime kit needs to be installed on the client machine. Instructions for configuring the network licence are detailed in the following page: This is required even if the simulations are to be performed on the server. If the TUFLOW licence is a network licence, the computer hosting the dongle will need to be configured as a TUFLOW server. CodeMeter support staff have advised that this can be done with the following parameters:ĬodeMeterRuntime.exe /ComponentArgs '*':'/qn' Configuring Network Server
#What is codemeter runtime kit install#
It is possible to do a silent install of the CodeMeter Runtime kit. For a network licence, continue to the configure network server and configure network access sections below.For a local licence, the dongle can now be inserted into the machine and TUFLOW simulations can be started.If there is already an active licence associated with the dongle:.Please progress to the Request a licence update section You will need to update your licence file. If this is the first time the licence has been used, or your existing licence has expired.Once installed the configuration depends on if the TUFLOW licence is a Local or Network licence. The correct file to download is the CodeMeter Runtime Kit for Windows The latest version can be downloaded from CodeMeter site: If you are installing on a Linux computer from the command line, refer to Installing Wibu CodeMeter Linux
![what is codemeter runtime kit what is codemeter runtime kit](https://cdn.wibu.com/fileadmin/images/2-Products/CodeMeter/CodeMeterWebAdmin_Screenshot.png)
This needs to be installed for any computers that will be running TUFLOW (from either local or network licence) as well as for the network licence server. The first step in using the Wibu licence is to install the CodeMeter Runtime Kit. This page contains a brief introduction to the Wibu dongles. To use the LG Mobile Support tool, select your operating system below to download then install: Windows Unlock your device and connect to a PC using a USB cable (you may use the cable attached to your LG charger). Here you can find Runtime software for Wibu-Systems products CodeMeter and WibuKey for Windows, Mac and Linux operating systems.